Vue de la page 0
NME1254 & FME1504
January 2000
Page 1
INTRODUCTION
To the owner or user: The service manual you are
reading is intended to provide you, and the
maintenance or service technician, with the
information needed to install, start up, clean,
maintain, and service either ice system.
Both models feature: front service for the
evaporator, gearmotor, control box, water reservoir
and bin control; electronic circuitry for monitoring
ice and water level; a thermostatic expansion
valve; and R-404A as the refrigerant.
Table of Contents
FOR THE INSTALLER ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 2
FOR THE INSTALLER: Environmental Limitations ,,,,,,,,,,,,,,,,,,,,, Page 3
FOR THE INSTALLER ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 4
FOR THE PLUMBER ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 5
FOR THE ELECTRICIAN ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 6
FOR THE INSTALLER: Final Check List ,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 7
START UP ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 8
COMPONENT DESCRIPTION ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 9
Control Box ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 10
ELECTRICAL SEQUENCE: ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 11
COMPONENT DESCRIPTION ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 12
OPERATION ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 13
OPERATION: Refrigeration ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 14
CLEANING & SANITIZING ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 15
SENSOR and CONDENSER MAINTENANCE ,,,,,,,,,,,,,,,,,,,,,,,, Page 16
BEARING MAINTENANCE ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 17
AUGER MAINTENANCE ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 18
SERVICE DIAGNOSIS: ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 19
SERVICE DIAGNOSIS ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 20
CONTROL SYSTEM DIAGNOSTICS ,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 21
REMOVAL AND REPLACEMENT: Water Reservoir & Bin Control ,,,,,,,,,,,,, Page 22
REMOVAL AND REPLACEMENT: Bearing And Breaker ,,,,,,,,,,,,,,,,,, Page 23
REMOVAL AND REPLACEMENT: Auger ,,,,,,,,,,,,,,,,,,,,,,,,,, Page 24
REMOVAL AND REPLACEMENT: Water Seal ,,,,,,,,,,,,,,,,,,,,,,, Page 25
REMOVAL AND REPLACEMENT: Evaporator ,,,,,,,,,,,,,,,,,,,,,,, Page 26
REMOVAL AND REPLACEMENT: Gearmotor ,,,,,,,,,,,,,,,,,,,,,,,, Page 27
Refrigeration System Service ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 28
What to Do Before Calling for Service ,,,,,,,,,,,,,,,,,,,,,,,,,,,, Page 29
This manual was printed on recycled paper.
Keep it for future reference.
Note this symbol when it appears.
It marks a potential hazard.
Vue de la page 0
1 2 3 4 5 6 ... 28 29

Résumé du contenu

Page 1 - NME1254 & FME1504

NME1254 & FME1504January 2000Page 1INTRODUCTIONTo the owner or user: The service manual you arereading is intended to provide you, and themaintena

Page 2

Control BoxContactor: A definite purpose contactorconnecting the compressor to the power supply.Circuit Board: Controlling the ice machinethrough sens

Page 3

ELECTRICAL SEQUENCE:There are 7 indicator lights on the control board:·WTR-OK (Water OK). Green. Normal =Glowing. Glows when there is water in therese

Page 4

COMPONENT DESCRIPTIONEvaporator: A refrigerated vertical tube filledwater and containing a water seal and auger.Auger: A solid stainless steel double

Page 5

OPERATIONWaterWater enters the machine through the 3/8" maleflare at the rear of the cabinet, goes to the waterreservoir which it enters through

Page 6

OPERATION: RefrigerationBeginning at the compressor, the refrigerant iscompressed into a high temperature gas. Thedischarge line directs this gas to t

Page 7

CLEANING & SANITIZINGA Scotsman Ice System represents a sizable investment of time and money in any company’s business.In order to receive the bes

Page 8

1. The bin control is a device that senses light,and must be kept clean enough so that they can“see”. At least twice a year, remove the bin controlsen

Page 9

BEARING MAINTENANCEThe bearing in the breaker should also be checkedat least two times per year.A. Check the bearing by:·removing the ice chute cover·

Page 10

In some areas, the water supply to the Ice Machinewill contain a high concentration of minerals, andthat will result in an evaporator and augerbecomin

Page 11

NME1254 & FME1504January 2000Page 19SERVICE DIAGNOSIS:Symptom Possible Cause Probable CorrectionNo ice is made, nothing operates Unit off due to n

Page 12

FOR THE INSTALLERThese machines are designed to fit the followingScotsman storage bins:·SB480 andextensions (with bin top KBT18)·HTB555 or BH550 - dir

Page 13

NME1254 & FME1504June 2002Page 20SERVICE DIAGNOSISSymptom Possible Cause Probable CorrectionWater Leak Drain plugged up Clean out drainTubing crac

Page 14

CONTROL SYSTEM DIAGNOSTICSThe control system consists of:·Control Board·Water Sensor·Ice Sensors·High Pressure Cut Out·Low Pressure Cut OutIf the unit

Page 15

WATER RESERVOIR1. Shut off the water supply to the ice machine.2. Remove front panel.3. Remove reservoir cover.4. Disconnect water inlet tube from res

Page 16

REMOVAL AND REPLACEMENT: Bearing And BreakerNote: Removal of the auger, water seal, evaporatorand gearmotor must begin at the top of theassembly.To Re

Page 17

To Remove the Auger:Turn off the water to the machine, and unclip theevaporator drain hose, pull it down and drain theevaporator into the bin or a con

Page 18

To Remove the Water Seal:(Assuming all steps to remove the auger havebeen performed.)1. The gearmotor/evaporator assembly will have tobe exposed.2. Re

Page 19

To Replace the Evaporator:(Assuming all the steps for removal of the thrustbearing, breaker, auger, and water seal have beenperformed.)1. Recover the

Page 20

To Check the Motor:1. Remove wires from terminals 1 and 2.2. Use an ohmmeter to check for continuity. If thereis none, replace the motor only. If ther

Page 21

Refrigeration System ServiceNME1254 & FME1504June 2002Page 28General: This ice machine uses R-404A refrigerantand polyolester oil. Do NOT use mine

Page 22

What to Do Before Calling for ServiceIf the machine is off, not making ice:1. Check the water supply to the ice machine. Themachine is designed to shu

Page 23

Installation Limitations:This ice system is designed to be installed indoors,in a controlled environment:Min. Max.Air Temperature 500F 1000FWater Temp

Page 24

FOR THE INSTALLERLocationAfter uncrating and inspection, the unitis ready for installation. It is importantthat the machine be installed in alocation

Page 25

FOR THE PLUMBERCONFORM TO ALL APPLICABLE CODESWater InletAir Cooled Models: Connect a water supply ofcold, potable water. Use 3/8" O.D. copper tu

Page 26

FOR THE ELECTRICIANCONFORM TO ALL APPLICABLE CODESConnect the electrical power to the power leads inthe junction box at the rear of the machine.Check

Page 27

FOR THE INSTALLER: Final Check List1. Is the ice system installed indoors in alocation where the air and watertemperatures are controlled, and where t

Page 28

START UPPre-Start Inspection1. Remove the front, and left side service panels.2. Check that the styrofoam shipping blocks underthe gearmotor, on top o

Page 29

COMPONENT DESCRIPTIONControl Box: Contains the electrical controls thatoperate the machine.Low Pressure Cut Out: An automatic reset switchset to shut