IntroductionTo the owner or user: This service manual isintended to provide you, and the maintenance orservice technician, with the information needed
InstallationFor The ElectricianThis unit must be on a separate 230 volt AC 60cycle single phase power supply. The maximumfuse size for this circuit is
After Utility Connections1. Level the cabinet, use the leg levelers on theend of the legs to adjust the cabinet height. (Legsshould have been installe
Component LocationMany components are serviceable from the frontwithout removing the side panels.Behind the front panel:• Water pump• Inlet water valv
Initial Start UpAfter the final check list has been gone through,the ice machine may be started up.1. Open the water shut off valve; the inlet waterva
Initial Start UpNote: If the first batch of cubes are not all uniformdiscs, some ice machine cleaner should be addedto the reservoir.1. After ice has
Maintenance, Cleaning and SanitizingCleaning Schedule:•Scrub the outside of the cabinet once a weekwith soap and water.•Sanitize the bin interior once
Cleaning: Ice Machine Water SystemDissolve and Remove Minerals:1. Remove front panel.2. Move the ICE/OFF/WASH switch to OFF.3. Remove the splash guard
How It Works:Refrigeration: Freeze Cycle:From the compressor, hot discharge gas ispumped to the remote air cooled condenser.At the condenser, if the d
Technical CharacteristicsTypical Cycle Time•17 minutes @ 70oF. air and 50oF. water•24 minutes @ 90oF. air and 70oF. waterTypical Harvest Ice Weight•4
Service Diagnosis:SYMPTOM POSSIBLE CAUSE PROBABLE FIXNo ice is made, nothing operates Unit off, due to no power Restore powerUnit off, due to ICE/OFF/
SpecificationsInformationregardingModelNumber, SerialNumber,Ampacity and MaximumFuse Size arelocated on thenameplateof theicemachine.Themodelnumber,se
SYMPTOM POSSIBLE CAUSE PROBABLE FIXNo ice compressor is operating No cooling due to low refrigerantchargeLocate leak, recover remainingrefrigerant, re
Service Diagnosis:SYMPTOM POSSIBLE CAUSE PROBABLE FIXIce is made, but will not harvest Will not harvest due to hot gasvalve not opening.Check for volt
Removal and ReplacementIce Size Thermostat:Before replacing the ice size thermostat, it shouldbe positively determined that it is at fault.1. Disconne
Removal and ReplacementWater PumpThe pump provides the force to move the waterfrom the reservoir to the freezing surface. Thepump does not need oil, b
Removal and Replacement: Refrigeration SystemGeneral InformationWork on the refrigeration system should only bedone when it is certain that the system
For The Installer: Environmental LimitationsThe ice machine must be installed indoors in acontrolled environment.Minimum MaximumAir Temp 550F. 1000F.W
InstallationWaterThe water supply for this ice machine has been incontact with many materials since it fell from thesky as rain. All rain is slightly
Capillary TubeBin ThermostatBracketFasten CabinetsTogether At BackWith Straps &Screws.Routing HoleStackingInstallation: Ice Storage BinAssembly:1.
Installation: SLD150 Hotel DispenserAssemblyThe ice machine must be placed onto the top ofthe dispenser, and the bin thermostat capillarytube routed i
Installation: Scotsman IS or RS DispenserAssembly:The assembly of the ice machine onto thedispenser requires two additional parts: an adapterkit and a
installationFor The PlumberSupply:Screw the 3/8" male flare (fitting shipped inpackage inside cabinet) into the 1/4" FPT fitting atthe back
Installation: Remote Condenser SystemRemote CondenserThe remote condenser may be located within 100equivalent feet of the ice machine (per theformula)
Commentaires sur ces manuels