Scotsman F0522 Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
F0522 500 lb Flake Ice Machine
Scotsman Ice Systems
775 Corporate Woods Parkway
Vernon Hills, IL 60061
1-800-SCOTSMAN
Fax: 847-913-9844
E-mail: customer.service@scotsman-ice.com
www.scotsman-ice.com
Specifications
Dimensions (W x D x H):
Unit:
22.9 x 24” x 23”
(58.2 x 61.0 x 58.4 cm)
Shipping Carton:
25.5 x 27.5 x 28.5”
(64.8 x 69.9 x 72.4 cm)
Shipping Weight:
173 lb/78 kg
BTU per hour:
5,000
Refrigerant:
R-404A
Operating Requirements
Air Temperatures
Water Temperatures
Remote Cond. Temps
Water Pressures
Electrical Voltage
50°F (10°C)
40°F (4.4°C)
-20°F (-29°C)
20 PSIG (1.4 bar)
-10%
Minimum Maximum
100°F (38°C)
100°F (38°C)
120°F (49°C)
80 PSIG (5.5 bar)
+10%
All Models
© 2009 Scotsman Ice Systems. SIS-SS-PRD-F0522
12-09
F0522A-1A
F0522W-1A
Air
Water
115/60/1
115/60/1
20
20
2
2
15.2
14.4
6.1
3.9
12.0/45.5
12.0/45.5
-
82/310.73
Model Number
Condenser
Unit
Basic Electrical
Volts/Hz/Phase
Max. Fuse Size
(amps)
Circuit
Wires
Min.
Circuit
Ampacity
Energy Consumption
kWh/100 lb (45.4 kg)
90˚F(32˚C)/70˚F(21˚C)
Water Usage
Gallons/100 lb (liters/45.4 kg)
Potable
90˚F(32˚C)/
70˚F(21˚C)
Condenser
90˚F(32˚C)/
70˚F(21˚C)
Specifications and design are subject to change without notice.
Accessories
Model Number Description
* Scotsman recommends all ice machines have water filtration. See Scotsman Sanitation Matrix for details.
The smart choice in ice.™
®
KVS
KSBU
KSBU-N
KPFSA223
Vari-Smart™ Ice Level Control - Program ice bin levels to match ice needs.
Smart-Board™ Advanced Control - Use additional operational data for fast diagnosis.
Smart-Board™ Advanced Control with Network - Network capable.
Side Air Flow Kit for 23 Tall Prodigy Flaker and Nugget
24.00
REF.
22.00 REF.
2.92
6.48
2.81
4.30
16.50
12.50
ICE DROP
OPENING
PLAN VIEW
ULTRA SONIC
BIN LEVEL
SENSOR
OPTIONAL
22.00
23.00
22.89
FRONT VIEW
LOUVER AND
REMOVABLE FILTER
A/C UNITS ONLY
24.00
.92
[2.4]
LEFT SIDE VIEW
12.40
2.68
1.59
14.65
2.17
AIR COOLED
BACK VIEW
3/4" FPT
DRAIN
.88 DIA.
ELECTRICAL
ACCESS
3/8" FLARE
MACHINE
WATER
INLET
12.35
2.17
1.59
2.63
14.55
19.31
17.55
3.33
15.40
WATER COOLED
BACK VIEW
3/8" FLARE
MACHINE
WATER
INLET
3/4" FPT
DRAIN
.88 DIA.
ELECTRICAL
CONNECTION
3/8" FPT
CONDENSER
WATER
INLET
1/2" FPT
CONDENSER
DRAIN
EXHAUST
AIR
INTAKE AIR
A/C UNITS ONLY
A/C UNITS
ONLY
* Installation Note: Allow 6” minimum space at back for utility connections.
Vue de la page 1