INTRODUCTIONThis manual is intended as a reference for theinstallation of a Scotsman ice maker modelsCME855 and the CME1000. TABLE OF CONTENTSSPECIFIC
INITIAL START UPIce Maker:1. Remove screws and front panel.2. Remove two screws and the control box cover.3. Remove the evaporator cover.4. Locate two
INITIAL START UPAdjust for the correct size if needed:To produce SMALLER sized ice cubes: Locate cube size control knob in the front of thecontrol box
ADJUSTMENT OF THE TIMER & SWITCH ASSEMBLYOne complete revolution of the cam on the timerrepresents eight minutes. If left as factory set, thetimed
DrierThermostaticExpansion ValveHot Gas ValveCondenserSuctionLineEvaporatorsCompressorHotGasLineRefrigeration System SchematicREFRIGERATION SYSTEM OPE
EvaporatorsWater Manifold andDistributorsReservoirWater PumpDrainInlet Water ValveWATER SYSTEM SCHEMATICWATER SYSTEM OPERATIONA fixed charge of water
COMPONENT DESCRIPTIONCompressor ContactorThe compressor contactor carries the compressorline current. The compressor contactor coil haspower whenever
COMPONENT DESCRIPTIONElectric Water Inlet Valve The water inlet solenoid valve fills the reservoirassembly with water. Excess water overflows outthe o
SERVICE SPECIFICATIONS: CME855AWhen servicing a machine, it’s helpful to comparethat unit’s operating characteristics to those of anew, clean, normall
SERVICE SPECIFICATIONS: CME1000AWhen servicing a machine, it’s helpful to comparethat unit’s operating characteristics to those of anew, clean, normal
CLEANINGA Scotsman Ice System represents a sizable investment of time and money in any company’s business. Inorder to receive the best return for tha
Serial NumberPlate BehindFront PanelAir InAir OutSPECIFICATIONSAlways refer to the nameplate, located on the backof the cabinet, for the:••model numbe
CLEANINGSANITIZE WATER SYSTEM1. Remove and discard all ice from the bin.2. Remove front panel.3. Drain the reservoir4. Prepare 2 gallons of an approve
SERVICE DIAGNOSISSYMPTOM POSSIBLE CAUSE PROBABLE CORRECTIONNo ice, machine does not run 1. No electrical power 1. Restore power2. Circuit breaker trip
SERVICE DIAGNOSISSYMPTOM POSSIBLE CAUSE PROBABLE CORRECTIONLow ice production 4. High head pressure, a result ofa dirty condenser 4. Clean water circu
REMOVAL AND REPLACEMENT Cube Size Control To remove the cube size control: 1. Remove front panel. 2. Remove cover from control box. 3. Trace capillary
REMOVAL AND REPLACEMENTWater Pump1. Remove front panel.2. Remove evaporator cover.3. Unplug water pump electrical connection.4. Remove thumb screw ret
VAPOR VAPOR TEMP. PRES. TEMP. PRESS.(DEG F) (PSIG) DEG F) (PSIG)-20 17 70 146-18 18 72 150-16 20 74 155-14 21 76 16
LIQUID CHARGING Instructions for R-404AIn preparation for charging, the low side hoseshould have a sight glass, and/or a restrictordevice (such as a &
UTILITY CONNECTION LOCATIONSCME855A & CME1000AOctober, 1994Page 3
FOR THE INSTALLER: Environmental LimitationsInstallation LimitationsThe ice making portion of this ice system isdesigned to be installed indoors , in
FOR THE INSTALLER: Machine & Bin AssemblyStorage Bin:After uncrating the ice storage bin, attach the legsto the bin:1. Use a portion of the carton
FROMHARDWAREPACKAGEFROMHARDWAREPACKAGESTACKING TWO CME 42" AIR COOLEDSTACKING TWO UNITSTo stack a 42" wide CME cuber onto a CME855A,CME1000A
FOR THE PLUMBERWater SupplyThe recommended water supply line is a 3/8-inchO.D. tubing with a minimum operating pressure of20 PSIG and a maximum of 80
FOR THE ELECTRICIAN: Electrical Connections See the NAMEPLATE for current requirements todetermine wire size to be used for electricalhookup. The cube
FOR THE INSTALLER: Final Check List1. Is the ice maker cabinet in a room whereambient temperatures are within the minimum andmaximum temperatures spec