For The Plumber
Drains:
The dispenser requires a gravity drain. The pitch
on the drain tubes must be at least 1/4 inch fall per
foot of horizontal run. On long horizontal runs, a
vent at the back of the cabinet will improve
draining, and is recommended.
There are two drains to connect: A sink drain, a
7
8
"
plastic tube; and the bin drain, a
5
8
" plastic tube.
Install rigid tubing between the machine and the
building drain. Route the drains separately to the
building drain.
Water supply:
Connect cold, potable water to the machine. A
hand valve near the location is recommended. A
water filter is also a good idea.
Follow all local codes.
FOLLOW ALL APPLICABLE LOCAL,
STATE AND NATIONAL CODES
Strainer or
Filter
Water Inlet Fitting
(Inside Cabinet)
Sink Drain
Bin and
Reservoir
Overflow Drains
Water Supply
Building Drain
(Typical)
TDE470