Scotsman FME800R Manuel de service Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can “see”. At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
3. The top bearing in the breaker should also be
checked at least two times per year.
Check the breaker bearing by:
removing the ice chute cover
unscrewing the ice sweep
removing the water shed
unscrewing the breaker cover (left hand thread)
unscrewing the auger stud
Inspect the assembly, looking for wear
4. Clean the remote condenser. Use a vacuum
cleaner or coil cleaner if needed.
Do NOT use a wire brush.
5. Check and tighten all bolts and screws.
MAINTENANCE AND CLEANING
WATER LEVEL
SENSOR
SLIDE UP
TO REMOVE
//////////////////////////////////////
CAUTION: THE TIP
IS MADE OF GLASS
///////////////////////////////////////
RESERVOIR
ICE CHUTE
ICE LEVEL
SENSORS
SLIDE LEFT TO
REMOVE
ICE
SWEEP
BREAKER
COVER
Electrical Shock
Hazard.
Electrical shock can
cause personal injury.
Disconnect electrical
power before beginning.
FME800R
August 1993
Page 21
Vue de la page 20