Scotsman F0522 Manuel de service Page 51

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 51
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 50
Repair Procedures: Thermostatic Expansion Valve
1. Remove front panel.
2. If the machine was in operation, push and
release the off button to shut it down.
3. Disconnect electrical power.
4.
Recover refrigerant.
5. Remove insulation covering expansion valve
and bulb.
6. Remove strap securing bulb to suction line.
7. Unsweat the expansion valve from the liquid
line. Remove it.
8. Unsweat the drier from the liquid line.
Remove it.
9. Connect nitrogen to discharge access valve.
10. Immediately place new valve in ice machine.
11. Open nitrogen bottle and braze expansion
valve inlet and outlet joints together. Braze
new drier into system.
12. Shut off nitrogen, shut access valves.
13. Evacuate to at least 300 microns.
14. Weigh in the nameplate charge. Check for
leaks.
15. Attach bulb to suction line. Position at 4 or 8
o'clock on the tube. Secure tightly but do not
crush the bulb with the strap.
16. Attach valve and bulb insulation.
17. Reconnect electrical power.
18. Return all panels to their original positions.
September 2009
Page 51
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Electrical Shock Hazard.
Disconnect electrical power
before beginning.
Vue de la page 50
1 2 ... 46 47 48 49 50 51

Commentaires sur ces manuels

Pas de commentaire