Water
The water supply for ice making must be cold,
potable water. There is a single 3/8” male flare
potable water connection on the back panel. Water
cooled models also have a 3/8” FPT inlet
connection for the water cooled condenser. Chilled
water can also be used for this connection.
Drain
There is one ¾” FPT condensate drain fitting at the
back of the cabinet. Water cooled models also
have a ½” FPT discharge drain connection on the
back panel.
Tubing
Connect the potable water supply to the potable
water fitting, 3/8” OD copper tubing or the
equivalent is recommended.
Water filtration is recommended. If there is an
existing filter, change the cartridge.
Connect the water cooled water supply to the
condenser inlet.
Note: Do NOT filter water to the water cooled
condenser circuit.
Connect the drain tube to the condensate drain
fitting.
Connect the water cooled condenser drain tube to
the condenser outlet.
Do not Tee ice machine drains into the drain tube
from the ice storage bin or dispenser. Back ups
could contaminate and / or melt the ice in the bin or
dispenser.
Follow all local and national codes for tubing, traps
and air gaps.
September 2009
Page 7
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Air Cooled Plumbing
Water Cooled Plumbing
Potable
Water
Condensate
Drain
Potable
Water
Condensate
Drain
Condenser
Water
Condenser
Drain