WATER RESERVOIR
1. Shut off the water supply to the icemaker.
2. Remove front panel and reservoir cover.
3. To remove float only, disconnect water inlet
compression fitting at reservoir inlet, push in on
locking tab, pull float up and out of the reservoir.
Note: there is a separate plunger/seat inside the
valve assembly that may be replaced.
4. To remove reservoir, disconnect water outlet at
reservoir base.
5. Remove drain hose from reservoir.
6. Remove water level sensor from reservoir.
7. Remove mounting screws from reservoir
bracket, and remove reservoir from icemaker.
8. Reverse to reassemble.
BIN CONTROLS (Ice Level Sensors)
1. Disconnect electrical power.
2. Remove front panel.
3. Remove control box cover.
4. Locate ice chute, at the base of the chute, in
front of and behind it are two plastic bin control
mounts.
5. Slide each bin control to the left, and in the
control box, disconnect the electrical leads
connecting the bin control to the circuit board.
6. Reverse to reassemble, be certain that the bin
controls are aligned so that the ice level sensors
are visible (centered) through the holes in the ice
chute.
FLOAT
ASSEMBLY
Valve
Seat/Plunger
LOCKING TAB
ICE
CHUTE
SLIDE BIN
CONTROLS IN
AND OUT
REMOVAL AND REPLACEMENT: Water Reservoir & Bin Controls