Options: Bin Thermostat
Another bin control method available on these
machines is a bin thermostat.
Type: Opens on temperature fall.
Connects: To blue wires to controller, in place of
the jumper connecting the blue wires between
terminals 5 and 6.
Use: In certain ice dispenser kits or whenever a
permanently lowered ice level is desired and a KVS
is not suitable.
Mounts: To the control box support post.
Result when open: Machine shuts down, b in code
display.
Results when closed: Machine makes ice until
either the circuit opens or the photo-eyes are
blocked by ice.
Circuit voltage type: Low
September 2009
Page 44
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Bin
Thermostat
Mounts Here