Vue de la page 38
Service Diagnosis - Remote
September 2009
Page 39
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Symptom Probable Cause Possible Correction
No ice
No power
If ice machine has power and power
light is out, check transformer.
Code 3: No water
Restore water, check filters, water
level and sensor
Status light is off Push and release ON switch
Code 1: No ice sensed
Check for ice flow down chute. if
very slow or no ice being made,
check for refrigeration system failure
Auger motor working, compressor
off. Check liquid line valve and
pump down switch
Check auger motor for power, if no
power, check controller component
indicator light. If there is power to
the motor, check motor windings or
start switch
Code 2: Auger motor draws too
many amps, controller shuts unit off.
Check liquid line valve for leak
through, causing auger to freeze in
place
Check for damage to gear reducer
or auger bearings.
Bin Eyes Blocked light is On
Ice is in the chute.
No ice in the chute. Check position
of sensors, check sensors for scale
build up
Code 4: High discharge pressure Check remote condenser fan motor
Code 4: Chute thermostat opened Unit overfilled, check photo eyes
Everything is in operation, but no
refrigeration effect
Check liquid line valve
Check compressor
Check TXV superheat
Check refrigerant charge
Optional ultrasonic system set too
low
Adjust selector switch to a higher
position
Optional bin thermostat is open
Check thermostat or jumper wire on
blue wires to #5 & #6
Optional ultrasonic system senses
false bin full
Check sensor for proper installation
and operation