IntroductionThese ice machines are the result of years ofexperience with flaked and nugget ice machines.The latest in electronics has been coupled wit
Remote Condenser Location - LimitsUse the following for planning the placement of thecondenser relative to the ice machineLocation Limits - condenser
For The Installer: Remote CondenserLocate the condenser as near as possible to theinterior location of the ice machine.Keep condenser at least 2 feet
Precharged Line RoutingDo not connect the precharged tubing until allrouting and forming of the tubing is complete. Seethe Coupling Instructions for f
Coupling InstructionsThe couplings on the ends of the pre-charged linesets are self-sealing when installed properly.Follow these instructions carefull
Final Check ListAfter connections,1. Wash out the bin. If desired, the interior of thebin could be sanitized.2. Locate the ice scoop (if supplied) and
ControllerSeptember 2009Page 15N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service ManualCleanCodeDisplayComponent Oper
AutoAlert and Display CodeThe controller uses indicator lights to provide theuser with information on Power, Status, Water orTime to Clean. These are
Component Indicator LightsThe controller has six lights to indicate componentoperation:Bin Eyes Blocked•This light is ON when the photo-electric icese
Electrical Component DetailsCompressor•Operated by the compressor contactor.Contactor•Operated by the controller. Line voltage coil.When energized the
RefrigerationRefrigerant: R-404ACompressors: Copeland or Tecumseh hermeticby modelExpansion valve: Non adjustable, internallyequalized.Condensers: Air
Installation:This machine is designed to be used indoors, in acontrolled environment. Operation outside the limitslisted here will void the warranty.A
Initial Start Up1. Turn the water supply on.2. Switch the electrical power on. Confirm voltageis correct for the model.3. Push and release the On butt
Sequence of OperationThe ice machine’s function is to continuouslyproduce ice until the ice level control senses thatthere is enough ice in the bin or
Refrigeration SystemThe refrigeration system is monitored by the highpressure cut out switch. If the refrigerationdischarge pressure exceeds the pre-s
Water SystemWater enters the machine through the 3/8" maleflare at the rear of the cabinet, goes to the waterreservoir which it enters through th
Air Cooled RefrigerationThe compressor concentrates the heat from icemaking into high pressure, hot discharge gas. Thehigh pressure forces the gas to
Water Cooled RefrigerationThe compressor concentrates the heat from icemaking into high pressure, hot discharge gas. Thehigh pressure forces the gas t
Remote Air Cooled RefrigerationThe compressor concentrates the heat from icemaking into high pressure, hot discharge gas. Thehigh pressure forces the
How Ice Is MadeRefrigeration effect is applied to the water betweenthe auger and the evaporator. When that water'stemperature drops to its freezi
Technical InformationPressure SwitchesCompressor Amp DrawAuger Drive Motor AmpsSeptember 2009Page 28N0422, F0522, N0622, F0822, N0922, F1222, N1322, F
December 2009Page 29N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service ManualHeat Load, Charge and Condenser GPMHeat L
Location:While the machine will operate satisfactorily withinthe air and water temperature limits, it will producemore ice when those temperatures are
Refrigeration System PressuresSeptember 2009Page 30N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service ManualRefrigerat
MaintenanceThis ice machine needs five types of maintenance:•Air cooled and remote models need their airfilters or condenser coils cleaned regularly.•
Maintenance: Scale RemovalNote: Following this procedure will reset thede-scale and sanitize light.1. Remove front panel.2. Push and release the Off b
Maintenance: Check Top BearingThis task should only be done by a qualifiedservice technicianThe bearing in the breaker should be checked atleast two t
Service Top BearingIf the grease is uniformly white, and the bearinghas no play, no further action is needed. If verygray, rusty, wet or has any embed
Check Gear Reducer LubricantAlthough there is no normal access to the gearreducer lubricant, it can be checked withoutremoval and complete disassembly
Maintenance: SensorsThe control that senses bin full and empty is aphoto-electric eye, therefore it must be kept cleanso it can “see”. At least twice
Service Diagnosis - Air CooledSeptember 2009Page 37N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service ManualSymptom Pr
Service Diagnosis - Water CooledSeptember 2009Page 38N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service ManualSymptom
Service Diagnosis - RemoteSeptember 2009Page 39N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service ManualSymptom Probab
F0522, F0822, N0522, or N0822 Cabinet LayoutSeptember 2009Page 4N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service Man
Service Diagnosis - RemoteSeptember 2009Page 40N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service ManualSymptom Probab
Service Diagnosis - Refrigeration System FailureSeptember 2009Page 41N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Servic
Service Diagnosis - Optional Ice Level ControlsVari-Smart (KVS)September 2009Page 42N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water o
OptionsVari-SmartOptional adjustable ice level control (KVS)When this option is present there is an adjustmentpost and an additional indicator light t
Options: Bin ThermostatAnother bin control method available on thesemachines is a bin thermostat.Type: Opens on temperature fall.Connects: To blue wir
Repair Procedures: Bearing And BreakerNote: Removal of the auger, water seal, evaporatorand gear reducer w/ motor must begin at the top ofthe assembly
Repair Procedures: The AugerTurn off the water to the machine, and unclip theevaporator drain hose, pull it down and drain theevaporator into the bin
Auger and Evaporator InspectionThe auger must be carefully inspected for wearand scale. The wear areas are the top bearingsurface, drive junction and
Repair Procedures: The Water Seal(Assuming all steps to remove the auger havebeen performed.)1. The gear reducer/evaporator assembly will haveto be ex
Repair Procedures: Replace the Evaporator:(Assuming all the steps for removal of the thrustbearing, breaker, auger, and water seal have beenperformed.
F1222, F1522, N1222 or N1522 Cabinet LayoutSeptember 2009Page 5N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522Air, Water or Remote Service Manu
Repair Procedures: The gear reducer(Assuming that the procedures through removal ofthe water seal have been performed.)1. Remove the electrical wires
Repair Procedures: Thermostatic Expansion Valve1. Remove front panel.2. If the machine was in operation, push andrelease the off button to shut it dow
Unpacking & Install PrepRemove the carton from the skid. Check for hiddenfreight damage, notify the carrier immediately if anyis found. Retain the
WaterThe water supply for ice making must be cold,potable water. There is a single 3/8” male flarepotable water connection on the back panel. Watercoo
ElectricalThe machine does not include a power cord, onemust be field supplied or the machine hard wired tothe electrical power supply. The junction b
Refrigeration - Remote Condenser ModelsRemote condenser models have additionalinstallation needs.The correct remote condenser fan and coil must beconn
Commentaires sur ces manuels