Service Diagnosis - Remote
September 2009
Page 40
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Symptom Probable Cause Possible Correction
Low ice making capacity
Scale build up
Remove scale from evaporator and
water system
High discharge pressure
Check remote condenser
Check headmaster
Expansion valve superheat incorrect Check superheat
Compressor cycles on and off
frequently
Check liquid line valve for leak
through
May be normal, pump down switch
will operate compressor as pump
down switch closes and opens